ECG Analysis that Doesn't Miss a Beat The ECG App packs a high-performance ECG sensor module, which provides single-lead ECG measurements, real-time analysis, and sinus rhythm, atrial fibrillation, and premature atrial and ventricular beat reminders, to stay informed and proactive about major heart health-related risks. |
HUAWEI TruSeen 5.0+ Heart Rate Monitoring HUAWEI TruSeen 5.0+ heart rate monitoring technology deploys eight photoelectric sensors deployed in a ring formation, with two groups of light sources, to boost anti-interference capabilities by converging different signals. |
Specifications
Dimensions
51 x 38 x 13.6 mm
*13.6 mm is the thickness of the watch measured at its thinnest point (the distance from the surface of the watch to the bottom cover, and does not include the sensor area).
Wrist Size
Strap width: 30 mm (width after gradient)
Strap Length: L-sized strap: about 133 mm long strap, about 90 mm short strap (including the buckle length), adapting to the wrist circumference of 161–200 mm
M-sized strap: about 118 mm long strap, about 90 mm short strap (including the buckle length), adapting to the wrist circumference of 130-160 mm
Strap material: Fluoroelastomer
Strap Color: Black
Weight
Approximately 40.9 g
Display
AMOLED color screen
Resolution: 456 x 280 pixels
Size: 1.64 inches
PPI 326
Watch Case
Graphite Black Aluminium Watch Case
Watch Strap
Black Fluoroelastomer Strap
Sensors
Accelerometer sensor
Gyroscope sensor
Optical heart rate sensor
Ambient light sensor
Temperature sensor
Differential pressure sensor
Hall sensor
Button
Full screen touch + side button(HOME button, HEALTH button)
Charging Port
Wireless
System Requirements
Android 6.0 or later
iOS 12.0 or later
Waterproof Level
IP68
Connectivity
GPS
NFC
Bluetooth 5.1
Environment
Ambient operating temperature: +5℃~+40℃
Charging
Wireless charging with integrated charging cradle
Battery Life
Typical usage: 7 days
Typical application scenarios: factory default settings, always-on heart rate (intelligent mode), scientific sleep at night, blood pressure measurement 6 times a day, ECG measurement 5 times a day, average weekly exercise 90 minutes, and message notification enabled (50 messages, 6 calls, 3 alarms per day) . The screen turns on 200 times a day. Actual battery life varies depending on usage habits.
In The Box
Device (with an L-sized strap and an L-sized airbag) x 1
M-sized airbag x 1
M-sized strap (without the buckle) x 1
Independent cover x 1
L-sized and M-sized airbag clothing (spare) x 1
Wrist circumference ruler x 1
User manual x 1
Wearing guide x 1
Charging cradle (with the power cable) x 1
*The preceding specifications are theoretical values based on product design. Some features and specifications may vary across markets. To provide accurate product information, specifications, and features, HUAWEI may make real-time adjustments to the preceding specifications, so that they match the product performance, specifications, indexes, and components of the actual product. Product information is subject to such changes and adjustments without notice.
Applicable wrist circumference
M-sized strap: 13.0–16.0 cm
L-sized strap: 16.1–20.0 cm
Note: If your wrist circumference exceeds 20.0 cm, the accuracy of blood pressure measurements may be affected.
[Warning]
1. Do not self-diagnose or treat yourself based on measurement results, as self-diagnosis may actually worsen your condition. Remember to follow the advice of medical professionals, and to send your results to medical professionals who are familiar with your health.
2. Do not wear the product during medical procedures, such as during magnetic resonance imaging (MRI) or the use of high-frequency medical devices. Keep the product away from any strong magnetic objects, or the product may fail.
3. The ECG feature on this product does not support asystole identification or ST segment detection.
4. In the event of arrhythmia (such as premature atrial or ventricular beats, or atrial fibrillation), bear in mind that the results may be inaccurate or inconclusive.
5. Diabetes, high cholesterol, and high blood pressure can affect peripheral circulation, and hence affect measurement results.
6. Blood pressure readings for users who suffer from blood circulation disorders or blood diseases are prone to error.
7. Avoid making newborns, infants who weigh less than 10 kg, or individuals who are unable to express themselves, wear or use this product.
8. The following groups should obtain blood pressure readings from this product, only under the supervision of a medical professional:
People who suffer from limb shaking syndrome, or whose arms are unable to bend on their own
People with wounds or inflammation on their arm or wrist
People whose arm or wrist is subject to an infusion, blood transfusion, or a catheter insertion
People who are currently wearing or using medical devices
[Precautions]
1. If the airbag is excessively inflated, it may cause discomfort to your wrist, and result in blood stasis or paralysis in extreme cases. In the event of overinflation, you should remove the device.
2. This device is not suitable for users who have pacemakers or other implantable devices.
3. Avoid measuring your blood pressure on the device too often, as doing so may affect blood circulation.
4. Device capabilities may be affected by portable and RF communication devices. Avoid placing the device near or on top of other devices, as doing so may increase radiation and undermine anti-interference capabilities.
5. This product may cause adverse events, such as allergies. In this case, stop wearing it and consult with a medical professional.
6. Metal implants in measured body parts may cause abnormal ECG signals.
7. Not applicable under conditions where flammable anesthetic gas mixed with air, oxygen, or nitrogen oxide.
8. Make sure that the electromagnetic interference is less than 3 V/m. Common sources of interference include microwave ovens and X-rays.
9. Before conducting an ECG measurement, make sure that the electrode surface of the product is clean. If the measurement fails multiple times, clean nearby skin and fingers with an alcohol solution.
10. This product may cause an adverse reaction in a small number of individuals, due to allergies, environmental factors, long-term exposure to irritants such as soap water or sweat, and other factors.
11. The device's ECG feature is only applicable for heart rate measurement and arrhythmia detection.